MeasureStar
Portable measurement instrument for capture and transmission of H2S concentration in air, to be used in:
- Sewer systems
- Industries
- Public water and sewage systems
Product Characteristics
- ATEX- certified for Zone 1
- Automatic reconfiguration up on exchange of instruments
- Measurement site may be managed from anywhere in the world via internet
- Data storage in the instrument of 440,000 measurements
- Measurement and transmission interval adjustable
- Extraordinary battery lifetime of up to 5 years MicroPower® technology
- Compact dimensions
- Rugged IP67casing with high resistance against chemicals
- Ultra low costs for start-up and operation
Technical data
- Range
H2S 0 – 500ppm or 0 – 1,000ppm; 0.1 – 0.25ppm resolution; 2% repeat accuracy - Range temperature
-10°C – 40°C - Ambient temperature
-10°C – 40°C - Storage and transportation temperature
-20°C – 70°C - Relative humidity
15% – 90% r.H - Ambient pressure
Barometric pressure +/-10% - Electromagnetic compatibility
EN61326 Class B - Safety requirements
EN61010-1 - Lifecycle of H2S sensor
24 month in air - Protection class
Sensor IP66, case IP67 - ATEX
II2 G EEx ib IIB T4 - Power supply
Battery pack BP417A - Measurement storage
440,000 measurements - Dimensions
H 230mm, W/D 90mm - Transmission
GPRS Quad-band - Indication
LED for instrument status
Accessories
Mounting rack, Anti-theft device, Antenna extension 5m, Battery pack L, Battery pack M, Battery pack S, Rechargeable battery, Charger, USB-cable, Magnetic key fob.
Tailor made quotations available upon request. Email your contact details to office@pollutionmonitors.co.uk and we will call you by return.